<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Personal Blog of Emre Yaşar &#187; RAID</title>
	<atom:link href="http://www.yasars.com/index.php/tag/raid/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.yasars.com</link>
	<description>A bit technical, a bit lifestyle..</description>
	<lastBuildDate>Tue, 27 Apr 2010 19:55:21 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8.4</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>RAID Write Policy</title>
		<link>http://www.yasars.com/index.php/2009/09/24/raid-writepolicy/</link>
		<comments>http://www.yasars.com/index.php/2009/09/24/raid-writepolicy/#comments</comments>
		<pubDate>Thu, 24 Sep 2009 12:21:17 +0000</pubDate>
		<dc:creator>Admin - Emre Yasar</dc:creator>
				<category><![CDATA[Genel]]></category>
		<category><![CDATA[RAID]]></category>
		<category><![CDATA[write policy]]></category>
		<category><![CDATA[write-back]]></category>
		<category><![CDATA[write-through]]></category>

		<guid isPermaLink="false">http://www.yasars.com/?p=209</guid>
		<description><![CDATA[Geçtiğimiz günlerde işyerinde DB admin arkadaşın bir Oracle veritabanı sunucusun yazma hızının diğer oracle vertiabanı sunucularına göre daha düşük olduğunu söylemesiyle kendimi RAID konfigürasyonuyla uğraşırken buldum.
Tabi bu noktaya gelmeden önce, gerçekten bir yavaşlık olup olmadığını tespit etmek için, SAN, FCP/iSCSI bağlantısı, RAID yapısı gibi faktörlerin test sonucu etkilemediğinden emin olmak için biraz uğraşmak gerekti.

Birkaç benchmarking [...]]]></description>
			<content:encoded><![CDATA[<p><img class="alignright size-medium wp-image-195" title="harddisk2_emreyasar" src="http://www.yasars.com/wp-content/uploads/2009/09/harddisk2_emreyasar-300x228.jpg" alt="harddisk2_emreyasar" width="300" height="228" />Geçtiğimiz günlerde işyerinde DB admin arkadaşın bir Oracle veritabanı sunucusun yazma hızının diğer oracle vertiabanı sunucularına göre daha düşük olduğunu söylemesiyle kendimi RAID konfigürasyonuyla uğraşırken buldum.</p>
<p>Tabi bu noktaya gelmeden önce, gerçekten bir yavaşlık olup olmadığını tespit etmek için, SAN, FCP/iSCSI bağlantısı, RAID yapısı gibi faktörlerin test sonucu etkilemediğinden emin olmak için biraz uğraşmak gerekti.</p>
<p><span id="more-209"></span></p>
<p>Birkaç benchmarking ve oracle tarafından sağlanan test araçları ile sunucuda gerçekten bir yavaşlık olduğunu tespit ettik.</p>
<p>Sunucu sistem kaynaklarının kullanımı ve disk I/O değerlerinde görünür bir problem yoktu. Dolayısıyla sıra RAID konfigürasyonuna gelmişti.</p>
<p>Sunucunun RAID writepolicy değeri writethrough olarak set edilmişti.  O an yavaşlığın sebebi belli olmuştu.</p>
<p>İşin hikaye kısmını geçersek;</p>
<p>Writepolicy değerini writeback olarak ayarlayıp birkaç test yaptıktan sonra sunucunun yazma hızında ciddi anlamda bir fark olduğunu tespit ettik.</p>
<p>Peki, nedir bu writeback(WB) ve writethrough(WT).</p>
<p>Bu iki yazma caching yöntemi arasında temel olarak şöyle bir fark var:</p>
<ul>
<li><strong>WT yönteminde</strong> veri bloğu RAID controller belleğine ve fiziksel diske aynı anda yazılır ve veri her iki alana da yazılana kadar yeni veri bloğu yazılmaya başlanmaz. RAID controller veriyi RAM hızlı bir şekilde yazmayı tamamlar ama verinin diske yazılması biraz daha zaman alacaktır.</li>
</ul>
<ul>
<li><strong>WB yönteminde</strong> ise veri bloğu ilk olarak RAID controller belleğine yazılır. Cache belleğinin dolması veya herhangi bir nedenle ihtiyaç olması durumunda veri diske yazılmaya başlanır. Diske veri yazma ihtiyacının çok sık olmamasından dolayı WB caching, WT caching’den daha yüksek bir yazma hızı sağlar.</li>
</ul>
<p>Ama..</p>
<p>Cache’lenen data, kısa bir süre olsa da, sadece RAID controller RAM&#8217;inde bulunduğu için, RAID kartı da pille beslenmiyorsa, enerji kesintisi esnasında o an cache’de bulunan data kaybolacaktır. Böyle bir durumda kaybolan verinin geri getirilebilmesi gibi bir imkanınız da olmayacaktır.</p>
<p><span style="text-decoration: underline;"><strong>Sonuç olarak:</strong></span></p>
<p><strong>Daha yüksek hızla yazma ihtiyacınız varsa RAID writepolicy olarak writeback kullanabilirsiniz. Fakat  writeback kullanıyorsanız RAID kartlarınızın pillerine daha fazla önem vermeniz gerekecektir.</strong></p>
]]></content:encoded>
			<wfw:commentRss>http://www.yasars.com/index.php/2009/09/24/raid-writepolicy/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Dell OpenManage ile RAID Konfigürasyonu</title>
		<link>http://www.yasars.com/index.php/2009/09/03/dell-openmanage-ile-raid-konfigurasyonu/</link>
		<comments>http://www.yasars.com/index.php/2009/09/03/dell-openmanage-ile-raid-konfigurasyonu/#comments</comments>
		<pubDate>Thu, 03 Sep 2009 16:13:43 +0000</pubDate>
		<dc:creator>Admin - Emre Yasar</dc:creator>
				<category><![CDATA[Genel]]></category>
		<category><![CDATA[Linux]]></category>
		<category><![CDATA[dell]]></category>
		<category><![CDATA[omconfig]]></category>
		<category><![CDATA[omreport]]></category>
		<category><![CDATA[open manage]]></category>
		<category><![CDATA[OpenManage]]></category>
		<category><![CDATA[RAID]]></category>

		<guid isPermaLink="false">http://www.yasars.com/?p=186</guid>
		<description><![CDATA[
Dell’in sunucu yönetim aracı olan OpenManage’i kullanıyorsanız birçok donanım parametresi değişikliğini kullandığınız işletim sistem üzerinden yapabilmeniz mümkün.
Yazının devamında bu işlemler ile ilgili birkaç örnek bulabilirsiniz:


İlk başta OpenManage ile sunucunun donanımsal durumu ile ilgili bilgi alalım.

eyasar1@test_sles10:~&#62; omreport chassis
Health
Main System Chassis
SEVERITY : COMPONENT
Ok       : Fans
Ok       : Intrusion
Ok       : Memory
Ok       : Power Supplies
Ok       : Processors
Ok       : Temperatures
Ok       : [...]]]></description>
			<content:encoded><![CDATA[<p><img class="alignright size-medium wp-image-195" title="harddisk2_emreyasar" src="http://www.yasars.com/wp-content/uploads/2009/09/harddisk2_emreyasar-300x228.jpg" alt="harddisk2_emreyasar" width="240" height="182" /></p>
<p>Dell’in sunucu yönetim aracı olan OpenManage’i kullanıyorsanız birçok donanım parametresi değişikliğini kullandığınız işletim sistem üzerinden yapabilmeniz mümkün.</p>
<p>Yazının devamında bu işlemler ile ilgili birkaç örnek bulabilirsiniz:</p>
<p><span id="more-186"></span></p>
<ul>
<li>İlk başta OpenManage ile sunucunun donanımsal durumu ile ilgili bilgi alalım.</li>
</ul>
<p><strong>eyasar1@test_sles10:~&gt; omreport chassis</strong></p>
<p>Health</p>
<p>Main System Chassis</p>
<p>SEVERITY : COMPONENT</p>
<p>Ok       : Fans</p>
<p>Ok       : Intrusion</p>
<p>Ok       : Memory</p>
<p>Ok       : Power Supplies</p>
<p>Ok       : Processors</p>
<p>Ok       : Temperatures</p>
<p>Ok       : Voltages</p>
<p>Ok       : Hardware Log</p>
<p>Ok       : Batteries</p>
<p>For further help, type the command followed by -?</p>
<hr />
<ul>
<li>Bu bileşenlerden herhangibiri ile ilgili daha detay bilgi görmek isteyebilirz:</li>
</ul>
<p><strong>eyasar1@test_sles10:~&gt; omreport chassis processors</strong></p>
<p>Processors Information</p>
<p>Health : Ok</p>
<p>Index             : 0</p>
<p>Status            : Ok</p>
<p>Connector Name    : CPU1</p>
<p>Processor Brand   : Intel(R) Xeon(R) CPU            5140  @ 2.33GHz</p>
<p>Processor Version : Model 15 Stepping 6</p>
<p>Current Speed     : 2333  MHz</p>
<p>State             : Present</p>
<p>Core Count        : 2</p>
<p>Index             : 1</p>
<p>Status            : Ok</p>
<p>Connector Name    : CPU2</p>
<p>Processor Brand   : Intel(R) Xeon(R) CPU            5140  @ 2.33GHz</p>
<p>Processor Version : Model 15 Stepping 6</p>
<p>Current Speed     : 2333  MHz</p>
<p>State             : Present</p>
<p>Core Count        : 2</p>
<hr />
<ul>
<li>Sunucu ile ilgili işe yarar bilgiler edinebileceğiniz birkaç komut daha verelim:</li>
</ul>
<p><strong>eyasar1@test_sles10:~&gt; omreport system summary</strong></p>
<p><strong>eyasar1@test_sles10:~&gt; omreport system esmlog</strong></p>
<p><strong>eyasar1@test_sles10:~&gt; omreport storage pdisk controller=0</strong></p>
<p>List of Physical Disks on Controller PERC 5/i Integrated (Embedded)</p>
<p>Controller PERC 5/i Integrated (Embedded)</p>
<p>ID                        : 0:0:0</p>
<p>Status                    : Ok</p>
<p>Name                      : Physical Disk 0:0:0</p>
<p>State                     : Online</p>
<p>Failure Predicted         : No</p>
<p>Progress                  : Not Applicable</p>
<p>Type                      : SAS</p>
<p>Capacity                  : 278.88 GB (299439751168 bytes)</p>
<p>Used RAID Disk Space      : 278.88 GB (299439751168 bytes)</p>
<p>Available RAID Disk Space : 0.00 GB (0 bytes)</p>
<p>Hot Spare                 : No</p>
<p>Vendor ID                 : DELL</p>
<p>Product ID                : ATLAS10K5_300SAS</p>
<p>Revision                  : BP00</p>
<p>Serial No.                : J80KQDAK</p>
<p>Negotiated Speed          : Not Available</p>
<p>Capable Speed             : Not Available</p>
<p>Manufacture Day           : 03</p>
<p>Manufacture Week          : 39</p>
<p>Manufacture Year          : 2006</p>
<p>SAS Address               : 50010B90003E450E</p>
<p>ID                        : 0:0:1</p>
<p>Status                    : Ok</p>
<p>Name                      : Physical Disk 0:0:1</p>
<p>State                     : Ready</p>
<p>Failure Predicted         : No</p>
<p>Progress                  : Not Applicable</p>
<p>Type                      : SAS</p>
<p>Capacity                  : 278.88 GB (299439751168 bytes)</p>
<p>Used RAID Disk Space      : 0.00 GB (0 bytes)</p>
<p>Available RAID Disk Space : 278.88 GB (299439751168 bytes)</p>
<p>Hot Spare                 : No</p>
<p>Vendor ID                 : DELL</p>
<p>Product ID                : ST3300655SS</p>
<p>Revision                  : S511</p>
<p>Serial No.                : 3LM0BLZF</p>
<p>Negotiated Speed          : Not Available</p>
<p>Capable Speed             : Not Available</p>
<p>Manufacture Day           : 06</p>
<p>Manufacture Week          : 51</p>
<p>Manufacture Year          : 2005</p>
<p>SAS Address               : 5000C500016522BD</p>
<hr /><strong>eyasar1@test_sles10:~&gt; omreport storage vdisk controller=0</strong></p>
<p>List of Virtual Disks on Controller PERC 5/i Integrated (Embedded)</p>
<p>Controller PERC 5/i Integrated (Embedded)</p>
<p>ID                  : 0</p>
<p>Status              : Ok</p>
<p>Name                : Boot</p>
<p>State               : Ready</p>
<p>Progress            : Not Applicable</p>
<p>Layout              : RAID-10</p>
<p>Size                : 557.75 GB (598879502336 bytes)</p>
<p>Device Name         : /dev/sda</p>
<p>Type                : SAS</p>
<p>Read Policy         : No Read Ahead</p>
<p>Write Policy        : Write Through</p>
<p>Cache Policy        : Not Applicable</p>
<p>Stripe Element Size : 64 KB</p>
<p>Disk Cache Policy   : Disabled</p>
<p>ID                  : 1</p>
<p>Status              : Ok</p>
<p>Name                : u04</p>
<p>State               : Ready</p>
<p>Progress            : Not Applicable</p>
<p>Layout              : RAID-0</p>
<p>Size                : 278.88 GB (299439751168 bytes)</p>
<p>Device Name         : /dev/sdb</p>
<p>Type                : SAS</p>
<p>Read Policy         : No Read Ahead</p>
<p>Write Policy        : Write Through</p>
<p>Cache Policy        : Not Applicable</p>
<p>Stripe Element Size : 64 KB</p>
<p>Disk Cache Policy   : Disabled</p>
<hr />
<ul>
<li>Şimdi sıra geldi RAID parametrelerini OpenManage yardımıyla işletim sistemi ortamında değiştirmeye.</li>
</ul>
<ul>
<li>Örneğin, RAID kartının yazma politikasını (write policy) “Write Back” yapalım:</li>
</ul>
<p><strong>eyasar1@test_sles10:~&gt; omconfig storage vdisk action=changepolicy controller=0 vdisk=1 writepolicy=wb</strong></p>
<hr />
<ul>
<li>Yaptığımız değişikliğin geçerli olup olmadığını aşağıdaki komutla kontrol edebiliriz:</li>
</ul>
<p><strong>eyasar1@test_sles10:~&gt; omreport storage vdisk controller=0</strong></p>
<hr />
<ul>
<li>İkinci RAID kontrolörünün sıfırıncı array’indeki birinci diski global hot spare olarak atamak için aşağıdaki komutu çalıştırabiliriz:</li>
</ul>
<p><strong>eyasar1@test_sles10:~&gt; omconfig storage adisk action=assignglobalhotspare controller=2 adisk=0:1 assign=yes</strong></p>
<hr />
<ul>
<li>İkinci RAID kontrolörünün sıfırıncı array’indeki birinci diskin hangi disk olduğunu bilmiyorsanız aşağıdaki komutu kullanarak disk’a ait LED’i yakabilir ve hangi disk olduğunu tespit edebilirsiniz:</li>
</ul>
<p><strong>eyasar1@test_sles10:~&gt; omconfig storage adisk action=blink controller=2 adisk=0:1</strong></p>
<hr />
<ul>
<li>Görüldüğü gibi OpenManage kullanrak işletim sisteminden donanımsal parametreleri değiştirebilmek mümkün.</li>
</ul>
<div id="_mcePaste" style="overflow: hidden; position: absolute; left: -10000px; top: 0px; width: 1px; height: 1px;"><!--[if gte mso 9]><xml> <w:WordDocument> <w:View>Normal</w:View> <w:Zoom>0</w:Zoom> <w:PunctuationKerning /> <w:ValidateAgainstSchemas /> <w:SaveIfXMLInvalid>false</w:SaveIfXMLInvalid> <w:IgnoreMixedContent>false</w:IgnoreMixedContent> <w:AlwaysShowPlaceholderText>false</w:AlwaysShowPlaceholderText> <w:Compatibility> <w:BreakWrappedTables /> <w:SnapToGridInCell /> <w:WrapTextWithPunct /> <w:UseAsianBreakRules /> <w:DontGrowAutofit /> </w:Compatibility> <w:BrowserLevel>MicrosoftInternetExplorer4</w:BrowserLevel> </w:WordDocument> </xml><![endif]--><!--[if gte mso 9]><xml> <w:LatentStyles DefLockedState="false" LatentStyleCount="156"> </w:LatentStyles> </xml><![endif]--><!--  /* Style Definitions */  p.MsoNormal, li.MsoNormal, div.MsoNormal 	{mso-style-parent:""; 	margin:0cm; 	margin-bottom:.0001pt; 	mso-pagination:widow-orphan; 	font-size:12.0pt; 	font-family:"Times New Roman"; 	mso-fareast-font-family:"Times New Roman";} @page Section1 	{size:612.0pt 792.0pt; 	margin:72.0pt 90.0pt 72.0pt 90.0pt; 	mso-header-margin:35.4pt; 	mso-footer-margin:35.4pt; 	mso-paper-source:0;} div.Section1 	{page:Section1;} --><!--[if gte mso 10]> <mce:style><!   /* Style Definitions */  table.MsoNormalTable 	{mso-style-name:"Normal Tablo"; 	mso-tstyle-rowband-size:0; 	mso-tstyle-colband-size:0; 	mso-style-noshow:yes; 	mso-style-parent:""; 	mso-padding-alt:0cm 5.4pt 0cm 5.4pt; 	mso-para-margin:0cm; 	mso-para-margin-bottom:.0001pt; 	mso-pagination:widow-orphan; 	font-size:10.0pt; 	font-family:"Times New Roman"; 	mso-ansi-language:#0400; 	mso-fareast-language:#0400; 	mso-bidi-language:#0400;} --> <!--[endif]--></p>
<p class="MsoNormal"><span style="font-size: 10pt;" lang="TR">Dell’in sunucu yönetim aracı olan OpenManage’i kullanıyorsanız birçok donanım parametresi değişikliğini kullandığınız işletim sistem üzerinden yapabilmeniz mümkün.</span></p>
<p class="MsoNormal"><span style="font-size: 10pt;" lang="TR">Yazının devamında bu işlemler ile ilgili birkaç örnek bulabilirsiniz:</span></p>
<p class="MsoNormal"><span style="font-size: 10pt;" lang="TR"><span> </span></span></p>
<p class="MsoNormal"><span style="font-size: 10pt;" lang="TR">İlk başta OpenManage ile sunucunun donanımsal durumu ile ilgili bilgi alalım.</span></p>
<p class="MsoNormal"><span style="font-size: 10pt;" lang="TR"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">eyasar1@test_sles10:~&gt; omreport chassis</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Health</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Main System Chassis</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">SEVERITY : COMPONENT</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Ok<span> </span>: Fans</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Ok<span> </span>: Intrusion</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Ok<span> </span>: Memory</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Ok<span> </span>: Power Supplies</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Ok<span> </span>: Processors</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Ok<span> </span>: Temperatures</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Ok<span> </span>: Voltages</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Ok<span> </span>: Hardware Log</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Ok<span> </span>: Batteries</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">For further help, type the command followed by -?</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt;">Bu bileşenlerden herhangibiri ile ilgili daha detay bilgi görmek isteyebilirz:</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">eyasar1@test_sles10:~&gt; omreport chassis processors</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Processors Information</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Health : Ok</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Index<span> </span>: 0</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Status<span> </span>: Ok</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Connector Name<span> </span>: CPU1</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Processor Brand<span> </span>: Intel(R) Xeon(R) CPU<span> </span>5140<span> </span>@ 2.33GHz</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Processor Version : Model 15 Stepping 6</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Current Speed<span> </span>: 2333<span> </span>MHz</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">State<span> </span>: Present</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Core Count<span> </span>: 2</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Index<span> </span>: 1</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Status<span> </span>: Ok</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Connector Name<span> </span>: CPU2</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Processor Brand<span> </span>: Intel(R) Xeon(R) CPU<span> </span>5140<span> </span>@ 2.33GHz</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Processor Version : Model 15 Stepping 6</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Current Speed<span> </span>: 2333<span> </span>MHz</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">State<span> </span>: Present</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Core Count<span> </span>: 2</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt;">Sunucu ile ilgili işe yarar bilgiler edinebileceğiniz birkaç komut daha verelim:</span></p>
<p class="MsoNormal"><span style="font-size: 10pt;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">eyasar1@test_sles10:~&gt; omreport system summary</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">eyasar1@test_sles10:~&gt; omreport system esmlog</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">eyasar1@test_sles10:~&gt; omreport storage pdisk controller=0</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">List of Physical Disks on Controller PERC 5/i Integrated (Embedded)</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Controller PERC 5/i Integrated (Embedded)</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">ID<span> </span>: 0:0:0</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Status<span> </span>: Ok</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Name<span> </span>: Physical Disk 0:0:0</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">State<span> </span>: Online</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Failure Predicted<span> </span>: No</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Progress<span> </span>: Not Applicable</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Type<span> </span>: SAS</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Capacity<span> </span>: 278.88 GB (299439751168 bytes)</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Used RAID Disk Space<span> </span>: 278.88 GB (299439751168 bytes)</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Available RAID Disk Space : 0.00 GB (0 bytes)</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Hot Spare<span> </span>: No</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Vendor ID<span> </span>: DELL</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Product ID<span> </span>: ATLAS10K5_300SAS</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Revision<span> </span>: BP00</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Serial No.<span> </span>: J80KQDAK</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Negotiated Speed<span> </span>: Not Available</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Capable Speed<span> </span>: Not Available</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Manufacture Day<span> </span>: 03</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Manufacture Week<span> </span>: 39</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Manufacture Year<span> </span>: 2006</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">SAS Address<span> </span>: 50010B90003E450E</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">ID<span> </span>: 0:0:1</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Status<span> </span>: Ok</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Name<span> </span>: Physical Disk 0:0:1</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">State<span> </span>: Ready</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Failure Predicted<span> </span>: No</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Progress<span> </span>: Not Applicable</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Type<span> </span>: SAS</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Capacity<span> </span>: 278.88 GB (299439751168 bytes)</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Used RAID Disk Space<span> </span>: 0.00 GB (0 bytes)</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Available RAID Disk Space : 278.88 GB (299439751168 bytes)</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Hot Spare<span> </span>: No</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Vendor ID<span> </span>: DELL</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Product ID<span> </span>: ST3300655SS</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Revision<span> </span><span> </span>: S511</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Serial No.<span> </span>: 3LM0BLZF</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Negotiated Speed<span> </span>: Not Available</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Capable Speed<span> </span>: Not Available</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Manufacture Day<span> </span>: 06</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Manufacture Week<span> </span>: 51</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Manufacture Year<span> </span>: 2005</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">SAS Address<span> </span>: 5000C500016522BD</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">eyasar1@test_sles10:~&gt; omreport storage vdisk controller=0</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">List of Virtual Disks on Controller PERC 5/i Integrated (Embedded)</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Controller PERC 5/i Integrated (Embedded)</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">ID<span> </span>: 0</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Status<span> </span><span> </span>: Ok</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Name<span> </span>: Boot</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">State<span> </span>: Ready</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Progress<span> </span>: Not Applicable</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Layout<span> </span>: RAID-10</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Size<span> </span>: 557.75 GB (598879502336 bytes)</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Device Name<span> </span>: /dev/sda</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Type<span> </span>: SAS</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Read Policy<span> </span><span> </span>: No Read Ahead</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Write Policy<span> </span>: Write Through</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Cache Policy<span> </span>: Not Applicable</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Stripe Element Size : 64 KB</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Disk Cache Policy<span> </span>: Disabled</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">ID<span> </span>: 1</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Status<span> </span>: Ok</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Name<span> </span>: u04</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">State<span> </span>: Ready</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Progress<span> </span>: Not Applicable</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Layout<span> </span>: RAID-0</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Size<span> </span>: 278.88 GB (299439751168 bytes)</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Device Name<span> </span>: /dev/sdb</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Type<span> </span>: SAS</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Read Policy<span> </span>: No Read Ahead</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Write Policy<span> </span>: Write Through</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Cache Policy<span> </span>: Not Applicable</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Stripe Element Size : 64 KB</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">Disk Cache Policy<span> </span>: Disabled</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt;">Şimdi sıra geldi RAID parametrelerini OpenManage yardımıyla işletim sistemi ortamında değiştirmeye.</span></p>
<p class="MsoNormal"><span style="font-size: 10pt;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt;">Örneğin, RAID kartının yazma politikasını (write policy) “Write Back” yapalım:</span></p>
<p class="MsoNormal"><span style="font-size: 10pt;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">eyasar1@test_sles10:~&gt; omconfig storage vdisk action=changepolicy controller=0 vdisk=1 writepolicy=wb</span></p>
<p class="MsoNormal"><span style="font-size: 10pt;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt;">Yaptığımız değişikliğin geçerli olup olmadığını aşağıdaki komutla kontrol edebiliriz:</span></p>
<p class="MsoNormal"><span style="font-size: 10pt;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">eyasar1@test_sles10:~&gt; omreport storage vdisk controller=0</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt;">İkinci RAID kontrolörünün sıfırıncı array’indeki birinci diski global hot spare olarak atamak için aşağıdaki komutu çalıştırabiliriz:</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">eyasar1@test_sles10:~&gt; omconfig storage adisk action=assignglobalhotspare controller=2 adisk=0:1 assign=yes</span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt;">İkinci RAID kontrolörünün sıfırıncı array’indeki birinci diskin hangi disk olduğunu bilmiyorsanız aşağıdaki komutu kullanarak disk’a ait LED’i yakabilir ve hangi disk olduğunu tespit edebilirsiniz:</span></p>
<p class="MsoNormal"><span style="font-size: 10pt;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt; font-family: &quot;Courier New&quot;;">eyasar1@test_sles10:~&gt; omconfig storage adisk action=unblink controller=2 adisk=0:1</span></p>
<p class="MsoNormal"><span style="font-size: 10pt;"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt;">Görüldüğü gibi OpenManage kullanrak işletim sisteminden donanımsal parametreleri değiştirebilmek mümkün.</span></p>
<p class="MsoNormal"><span style="font-size: 10pt;" lang="TR"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt;" lang="TR"> </span></p>
<p class="MsoNormal"><span style="font-size: 10pt;" lang="TR"> </span></p>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.yasars.com/index.php/2009/09/03/dell-openmanage-ile-raid-konfigurasyonu/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

